Sunday, 9 August 2009

SPA3102 and Swisscom

I've had a Linksys (nee sipura) spa3102 for a while (worked fine in the UK with sipgate) but havent got round to configuring it for switzerland yet.

Idiots guide seeing as I had trouble finding this on the net:

1) factory reset: ****, 73738#, 1#, hangup
2) make sure you have a computer in the NAT socket ('Ethernet') - I use mine bridged or into a main switch
3) http://192.168.0.1 and reset Router > WAN Setup > Enable WAN Web Server > YES
4) Router > LAN Setup > Networking Service > BRIDGE

http://www.3amsystems.com/wireline/daa-search.htm?country=Switzerland
helps a little
as does http://switzernet.com/public/070723-config_UA/spa-3102.php

Things I've changed are
Voice > Regional > TimeZone > "GMT +1"
Voice > Regional > FXS Port Impedance > "270+750||150nF"
Voice > Regional > Caller ID Method > ETSI FSK
Voice > Line 1 > Dialplan > (<#:>xx.<:@gw1>|xx.<:@gw0>)

This dialplan is because I wish to use swisscom pstn most of the time, but prefix with # if I want the call to go over the VOIP service

Particulate measurements near bushfires

Back in the 2019 Tasmanian bushfires we were lucky enough to be the other side of the Huon River from the fireground,  however we had a LOT...